Product Overview
Key Features
Applications
Technical Specifications
| Measurement Range | 0–0.6 kPa to 60 MPa (Gauge Pressure) 0–10 kPa to 3 MPa (Absolute Pressure) |
| Accuracy | ±0.075% FS, ±0.1% FS |
| Output Signal | 4–20 mA Two-wire System |
| Communication | Optional HART Protocol |
| Power Supply | 12–42 VDC (typically 24 VDC) |
| HART Power Supply | 15–42 VDC |
| Operating Temperature | -40 to 185°F (-40 to 85°C) |
| Medium Temperature | -40 to 212°F (-40 to 100°C) |
| Protection Rating | IP67 |
| Long-Term Stability | ±0.1% FS / 3 years |
| Display | Optional LCD Display |